Measuring Equipment Products
As a specialist in this segment we supply a wide range of measuring instruments, transducers and measuring transformers.
Measuring Equipment
- ACEIV..-EE-line meters with a moving iron are intended for measurement of AC currents or voltages with frequencies from 15 Hz to 100 Hz.1 .. 2500A, 250 .. 500V5A, 1A1.5
- DCDIV..-EE-line meters with a moving coil are intended for direct measurement or for connection to a separate shunt.0 .. 600A, 0 .. 400V1 .. 600A, 60mV, 0-20mA, 4-20mA, 10V1.5
- DCDIV..-E 240E-line meters with a moving coil are intended for direct measurement or for connection to a separate shunt.On request1 .. 600A, 60mV, 0-20mA, 4-20mA, 10V1.5
- DCDGIV..-EE-line moving coil meter with rectifier are used to measure ac current and voltage with a frequency of 40 up to 5000 Hz.On requestOn request1.5
- DCDGIV..-E 240E-line moving coil meter with rectifier are used to measure ac current and voltage with a frequency of 40 up to 5000 Hz.On requestOn request1.5
- BIV..-EBimetal maximum current E-Line meters with a bimetal measuring system are intended for testing thermal load of transformers, cables, electrical machines, etc.On requestOn request3
- BEIV..-ECombined bimetal maximum current E-Line meters are provided with a built-in bimetal system and a system with a moving ironOn requestOn request3
- FIS96-EE-line reed frequency meters in which the frequency of the incoming signal makes the reeds resonate.47-53Hz or 57-63Hz or 45-55Hz or 55-65Hz110, 230, 400 or 500V13 or 21
- FISD96-EE-line double reed frequency meters in which the frequency of the incoming signal makes the reeds resonate.2x 47-53Hz or 2x 57-63Hz or 2x 45-55Hz or 2x 55-65Hz110, 230, 400 or 500V2 x 13 or 2 x 21
- WFIV..-EE-line pointer frequency meters are suitable for all types of marine applications. The meters are intended for measurement of frequencies in the range from 45Hz to 65Hz.45-65Hz
- UIS..-EE-line hour meters show operation time of machines, equipment and other devices. When you need accurate information for testing, maintenance or warranty purposes, choose from our wide range of ELEQ hour meters50, 60Hz230, 400 or 6-30Vdc
- WDIV96-EE-line hour meters show operation time of machines, equipment and other devices. When you need accurate information for testing, maintenance or warranty purposes, choose from our wide range of ELEQ hour meters50, 60HzOn requestOn request
- CDIV96-EE-line hour meters show operation time of machines, equipment and other devices. When you need accurate information for testing, maintenance or warranty purposes, choose from our wide range of ELEQ hour meters50, 60HzOn requestOn request
- TMB800The TMB is a split-core current transformer and a permanently surface mounted ammeter provided with a sliding pointer to determine the maximum power consumeting in the past period.60-1000A≤ 60x35mmø 8–35mm
- TMB2000The TMB is a split-core current transformer and a permanently surface mounted ammeter provided with a sliding pointer to determine the maximum power consumeting in the past period.300-2000A≤ 80x32mmø 10–32mm
- FEIS96-E and FDIS96-EE-line FEIS96-E and FDIS96-E can signal minimal and maximal setting limits (MIN and MAX). The meter is provided with two output relays of 600 VA switching power.On requestOn request230V, 110V, 24Vdc
- ø 24,5EM223The ELEQ EM223 is a current transducer for converting an alternating current of up to 400A to a 0-20mA signal.Max. 400A0-20mADoes not require an auxiliary supply
- ø 24,5EM228The ELEQ EM228 is an active current transducer for converting an alternating current of up to 1250A to an 4-20mA (standard), 0-20mA or 0-10V signal.Max. 1250A4-20mA, 0-20mA and 0-10V (on request)230Vac
- ø 24,5EM229The ELEQ EM229 is an active current transducer for converting an alternating current of up to 250A to a 4-20mA, 0-20mA of 0-10V signal.Max. 250A4-20mA and 0-20mA and 0-10V230Vac
- ø 22,7EM238The ELEQ EM238 is a two-wire transmitter for converting alternating current to a 4-20mA signal. The auxiliary supply of 10-40Vdc is included in the output circuit.Max. 600A4-20mA10-40Vdc
- ø 24,5EMP4420The ELEQ EMP4420 is a two-wire transmitter for converting alternating current to a 4-20mA signal. The auxiliary supply of 10-40Vdc is included in the output circuit.Max. 600A4-20mA10-40Vdc
- ø 22,7EM303The ELEQ current relay EM303 is suitable for an alternating current of up to 100A and has a fixed switching point of 0.5A. Other switching points are available on customer specification.Max. 100A0,5A24Vdc, 110Vdc (on request)
- ø 22,7EM305The ELEQ current relay EM305 is suitable for an alternating current of up to 100A. The switching point and speed of response are adjustable.Max. 100AAdjustable24Vdc, 110Vdc (on request)
- MT416The MT416 is a freely programmable measurement transducer for measuring and monitoring RMS AC voltage and frequency. The MT416 can be programmed via a USB port.0-600V4-20mAAC (40-276Vac) or DC (24-300Vdc)
- MT418The MT418 is a freely programmable measurement transducer for measuring and monitoring RMS AC voltage.1A of 5A (12A max)4-20mAAC (40-276Vac) or DC (24-300Vdc)
- MI456The MI456 is a measurement transducer that converts DC voltage in to an 4-20mA output signal.50mVac, 24Vdc to 300Vdc1, 5, 10 or 20mA40-276Vac, 24-300Vdc
- MT440The MT440 is a freely programmable measurement transducer for measuring and monitoring single-phase or three-phase electrical networks for the purpose of industry or marine applications (BV approval).Voltage: 2-600V, Current 0-12,5AAvailable with up to four digital outputs that can be easily configured as analogue, relay, pulse or alarm outputs.
- ShuntsThe shunts of ELEQ are of high quality. Shunts can be used in combination with moving coil instruments to measure direct current.1 .. 2500A60mV0.5
- MT406The MT406 is a measurement transducer for measuring and monitoring AC voltage. The MT 406 requires no auxiliary supply.62,5..600V in normalized ranges0-20mARequires no auxiliary supply
- MT408The MT408 is a freely programmable measurement transducer for measuring and monitoring AC current. The MT408 requires no auxiliary supply.1A of 5A (12A max)0-20mARequires no auxiliary supply
- ACEIV..-EE-line meters with a moving iron are intended for measurement of AC currents or voltages with frequencies from 15 Hz to 100 Hz.1 .. 2500A, 250 .. 500V5A, 1A1.5
- DCDIV..-EE-line meters with a moving coil are intended for direct measurement or for connection to a separate shunt.0 .. 600A, 0 .. 400V1 .. 600A, 60mV, 0-20mA, 4-20mA, 10V1.5
- DCDIV..-E 240E-line meters with a moving coil are intended for direct measurement or for connection to a separate shunt.On request1 .. 600A, 60mV, 0-20mA, 4-20mA, 10V1.5
- DCDGIV..-EE-line moving coil meter with rectifier are used to measure ac current and voltage with a frequency of 40 up to 5000 Hz.On requestOn request1.5
- DCDGIV..-E 240E-line moving coil meter with rectifier are used to measure ac current and voltage with a frequency of 40 up to 5000 Hz.On requestOn request1.5
- BIV..-EBimetal maximum current E-Line meters with a bimetal measuring system are intended for testing thermal load of transformers, cables, electrical machines, etc.On requestOn request3
- BEIV..-ECombined bimetal maximum current E-Line meters are provided with a built-in bimetal system and a system with a moving ironOn requestOn request3
- FIS96-EE-line reed frequency meters in which the frequency of the incoming signal makes the reeds resonate.47-53Hz or 57-63Hz or 45-55Hz or 55-65Hz110, 230, 400 or 500V13 or 21
- FISD96-EE-line double reed frequency meters in which the frequency of the incoming signal makes the reeds resonate.2x 47-53Hz or 2x 57-63Hz or 2x 45-55Hz or 2x 55-65Hz110, 230, 400 or 500V2 x 13 or 2 x 21
- WFIV..-EE-line pointer frequency meters are suitable for all types of marine applications. The meters are intended for measurement of frequencies in the range from 45Hz to 65Hz.45-65Hz
- UIS..-EE-line hour meters show operation time of machines, equipment and other devices. When you need accurate information for testing, maintenance or warranty purposes, choose from our wide range of ELEQ hour meters50, 60Hz230, 400 or 6-30Vdc
- WDIV96-EE-line hour meters show operation time of machines, equipment and other devices. When you need accurate information for testing, maintenance or warranty purposes, choose from our wide range of ELEQ hour meters50, 60HzOn requestOn request
- CDIV96-EE-line hour meters show operation time of machines, equipment and other devices. When you need accurate information for testing, maintenance or warranty purposes, choose from our wide range of ELEQ hour meters50, 60HzOn requestOn request
- TMB800The TMB is a split-core current transformer and a permanently surface mounted ammeter provided with a sliding pointer to determine the maximum power consumeting in the past period.60-1000A≤ 60x35mmø 8–35mm
- TMB2000The TMB is a split-core current transformer and a permanently surface mounted ammeter provided with a sliding pointer to determine the maximum power consumeting in the past period.300-2000A≤ 80x32mmø 10–32mm
- FEIS96-E and FDIS96-EE-line FEIS96-E and FDIS96-E can signal minimal and maximal setting limits (MIN and MAX). The meter is provided with two output relays of 600 VA switching power.On requestOn request230V, 110V, 24Vdc
- ø 24,5EM223The ELEQ EM223 is a current transducer for converting an alternating current of up to 400A to a 0-20mA signal.Max. 400A0-20mADoes not require an auxiliary supply
- ø 24,5EM228The ELEQ EM228 is an active current transducer for converting an alternating current of up to 1250A to an 4-20mA (standard), 0-20mA or 0-10V signal.Max. 1250A4-20mA, 0-20mA and 0-10V (on request)230Vac
- ø 24,5EM229The ELEQ EM229 is an active current transducer for converting an alternating current of up to 250A to a 4-20mA, 0-20mA of 0-10V signal.Max. 250A4-20mA and 0-20mA and 0-10V230Vac
- ø 22,7EM238The ELEQ EM238 is a two-wire transmitter for converting alternating current to a 4-20mA signal. The auxiliary supply of 10-40Vdc is included in the output circuit.Max. 600A4-20mA10-40Vdc
- ø 24,5EMP4420The ELEQ EMP4420 is a two-wire transmitter for converting alternating current to a 4-20mA signal. The auxiliary supply of 10-40Vdc is included in the output circuit.Max. 600A4-20mA10-40Vdc
- ø 22,7EM303The ELEQ current relay EM303 is suitable for an alternating current of up to 100A and has a fixed switching point of 0.5A. Other switching points are available on customer specification.Max. 100A0,5A24Vdc, 110Vdc (on request)
- ø 22,7EM305The ELEQ current relay EM305 is suitable for an alternating current of up to 100A. The switching point and speed of response are adjustable.Max. 100AAdjustable24Vdc, 110Vdc (on request)
- MT416The MT416 is a freely programmable measurement transducer for measuring and monitoring RMS AC voltage and frequency. The MT416 can be programmed via a USB port.0-600V4-20mAAC (40-276Vac) or DC (24-300Vdc)
- MT418The MT418 is a freely programmable measurement transducer for measuring and monitoring RMS AC voltage.1A of 5A (12A max)4-20mAAC (40-276Vac) or DC (24-300Vdc)
- MI456The MI456 is a measurement transducer that converts DC voltage in to an 4-20mA output signal.50mVac, 24Vdc to 300Vdc1, 5, 10 or 20mA40-276Vac, 24-300Vdc
- MT440The MT440 is a freely programmable measurement transducer for measuring and monitoring single-phase or three-phase electrical networks for the purpose of industry or marine applications (BV approval).Voltage: 2-600V, Current 0-12,5AAvailable with up to four digital outputs that can be easily configured as analogue, relay, pulse or alarm outputs.
- MT406The MT406 is a measurement transducer for measuring and monitoring AC voltage. The MT 406 requires no auxiliary supply.62,5..600V in normalized ranges0-20mARequires no auxiliary supply
- MT408The MT408 is a freely programmable measurement transducer for measuring and monitoring AC current. The MT408 requires no auxiliary supply.1A of 5A (12A max)0-20mARequires no auxiliary supply