- ø 45TQ120TQ120 is a very compact split-core current transformer suitable for low voltage systems. The unit is easy to install while the top part can be removed entirely.100/1A .. 600/1A1 or 0,5S or 5P10 or 5P201,5 - 20 VA
- ø45TQ120TQ120 is a very compact split-core current transformer suitable for low voltage systems. The unit is easy to install while the top part can be removed entirely.200/5A .. 600/5A1 or 0,5S or 0,2S2,5 - 10 VA
- Max Ø 30,6Energy Revenue LineEasy to install current transformers for revenue metering that ensure lower engineering costs and eliminates paperwork of test reports.100/5A .. 1000/5A0,5S or 0,2S0 .. 5 VA
- Max Ø 30,6Energy Revenue Line for GermanyEasy to install current transformers for revenue metering that ensure lower engineering costs and eliminates paperwork of test reports. For Germany (mit Konformitätserklärung)100/5A .. 1000/5A and 100/1A .. 1000/1A0,5S or 0,2S0 .. 5 VA
- Ø 24,5IA60B31KThese – over the full operational temperature range - accurate current transformers are suitable for measurement and for revenue metering (billing)100/5A .. 600/5A0,2S0 .. 5 VA
- Ø 36IA70B41KThese – over the full operational temperature range - accurate current transformers are suitable for measurement and for revenue metering (billing)150/5A .. 600/5A0,2S0 .. 5 VA
- Ø 43IA85B61KThese – over the full operational temperature range - accurate current transformers are suitable for measurement and for revenue metering (billing)200/5A .. 1600/5A0,2S0 .. 5 VA
- Max. Ø 350GSA Cast Resin Current TransformerGSA Cast Resin Current Transformers: Perfect, safe design offering full flexibility in housing20 .. 10000AAccording to customer requirementAccording to customer requirement
- Ø 82SBM 106-54-82 ../1AThe SBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,5 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- Ø 82SBM 106-54-82 ../5AThe SBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,5 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- Ø 45SVA100 M-classesThe SVA100 is specially designed for application in medium voltage installations as RMU’s.50/5A .. 600/5A and 50/1A .. 600/1A0,2S or 0,5S or 12 .. 10 VA
- Ø 45SVA100 P-classesThe SVA100 is specially designed for application in medium voltage installations as RMU’s.50/5A .. 600/5A and 50/1A .. 600/1A5P10 or 10P101,5 .. 6VA
- Ø 50SVA105-100-50The SVA105 is especially designed for application in medium voltage installations around insulated cables.100/5A .. 600/5A and 100/1A .. 600/1A0,2S, 0,5S, 1, 5P10, 10P101,5-10VA
- Ø 50SVA150 B 50The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.200/5A0,2 FS515VA
- Ø 50SVA150 D 50The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1500/5A5P2030VA
- Ø 60SVA150 D 60The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1250/1A or 400-150/1/1A or 600-250/1/1A5P20, 0,2 - 10P105VA
- Ø 72 mmSVA150 C 72The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1000-500/1/15P2010-5VA
- Ø 110SVA170 B 110The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.100/1A10P102VA
- Max. Ø 50SVA100The low power switchgear current transformers in SVA100 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU).5P80, 10P80Contact ELEQ for details
- Max. Ø 73SVR109 H3The current transformer for self powered relay in SVR109 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU).5P80, 10P80Contact ELEQ for details
- Ø 100SVA160 A 100One-piece cast-resin CT suitable to put on cable or cable bushing: Type SVA for earth fault detection.60/1A or 100/1ASpecial for directed Earth fault2,5VA
- WSRThe load resistors have been specially developed to bring the charge of a current transformer within 25% and 100% of the value mentioned on the type plate of the power transformer.
- VSR600In its sealable module, the VSR600 load resistor simultaneously modifies the burden of all three phases according to the required values.
- WSR600In its sealable module, the VSR600 load resistor simultaneously modifies the burden of all three phases according to the required values.
- Max. Ø 350GSK Split-Core Current TransformerGSK Split-Core Current Transformers: perfect design offering full flexibility and compliance with all regulations.50 .. 10000AAccording to customer requirementAccording to customer requirement
- ø 35TM800The TM800 Split-core Current Transformer is suitable for cable and busbar.100/5A .. 800/5A1 or 3 or Fs51 - 15VA
- ø 32TM2000The TM2000 Split-core Current Transformer is suitable for cable and busbar.1000/5A .. 2000/5A0,5 or Fs71 - 15VA
- M6/M8ZK4-M6/M8With the ZK4-M6/M8 it is possible to make a safe and simple fused voltage branch in your distribution system.400Vac2A
- 0-16UAKWith the UAK it is possible to make a safe and simple fused voltage branch in your distribution system.690Vac10A
- ø7,5RM27The very compact RM27 is ideal for measuring low values with a high accuracy in locations where the dimensions are critical, for instance on a three phase circuit breaker with a fase distance of 17,5mm.35/1A and 64/1A10,2VA
- 1,5-16VCT32The ELEQ Power Sensor combines three functions in one product: the rail terminal, the current transformer and the fused voltage tap. So the VCT32 enables both an accurate current measurement and a voltage measurement in one product.16/1A, 35/1A and 64/1A0,5, 1, 30,1VA, 0,2VA
- M4/M5ZK4Voltage tap for shunt or rail can be used to make a safe and simple fused voltage tap in your distribution system.690Vac10A
- 2,5-6UAD6(n)This UAD6 easy voltage tap allows you to tap a fused voltage from an insulated wire for measurement using one hand and without the need for additional tools.400Vac2,5-6mm
- 16mm²UAD16(n)This UAD6 easy voltage tap allows you to tap a fused voltage from an insulated wire for measurement using one hand and without the need for additional tools.400Vac6-16mm
- 35mmSummation TransformerThe very compact and highly accurate Summation Transformer makes it possible to sum the outputs from 2 or 3 ELEQ TQ split-core transformers to 1 signal to your multi instrument.1+1/1A and 1+1+1/1A10,2VA
- M12 (40Nm)IGWThe IGW is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 36kV.5 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M20IGHSF 12The IGHSF 12 - head-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- M20IGHSF 24The IGHSF 24 - head-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- M12 (40Nm)IGWF D26The IGWF D26 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 600A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWF E43The IGWF E43 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWF E44The IGWF E44 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWF E46The IGWF E46 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- UGECAKT D2Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation.1,5 .. 22kV230V, other options available on request600 .. 750VA
- UGZCAKT D1The UGZCAKT D1 is a cast-resin insulated metal-coating indoor double-phase voltage transformer suitable for medium voltage switchgears.1,2 kV .. 11kV, other options available on request100V, 110V, 230V, other options available on requestAs required
- M10UGZT C1Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation.1,5 .. 11kV230V, other options available on request600 .. 750VA
- M10UGZT D2Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation.1,5 .. 11kV230V, other options available on request1300 .. 2000VA
- M10 (20Nm)UGE C1The UGE C1 is used for measurement and protection in applications, especially in medium-voltage switchgears. The single pole indoor voltage transformer can be used up to 17,5kV2/√3kV – 15,4/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGE D2The UGE D2 is used for measurement and protection in applications, especially in medium-voltage switchgears. The single pole indoor voltage transformer can be used up to 24kV.2/√3kV - 22/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGE D3The UGE D3 is used for measurement and protection in applications, especially in medium-voltage switchgears. The single pole indoor voltage transformer can be used up to 36kV.2/√3kV - 33/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- UGZ C1The UGZ C1 is used for measurement and protection in applications, especially in medium-voltage switchgears. The double pole indoor voltage transformer can be used up to 12kV.1,2kV - 11kV100V or 110V, other options available on requestAs required. For example 10, 15 or 30VA
- UGECAK D1The UGECAK is a medium voltage insulated voltage transformer with screening against electric fields which enables mounting with no phase distance. This product is cast resin insulated and touch-proved.11 / √3 kV100 / √3 V or 110 / √3 V, other options available on requestAs required For example 2,5, 5, 10, 15, 30VA
- UGECAK D2The UGECAK is a medium voltage insulated voltage transformer with screening against electric fields which enables mounting with no phase distance. This product is cast resin insulated and touch-proved.22 / √3 kV100 / √3 V or 110 / √3 V, other options available on requestAs required. For example 2,5, 5, 10, 15, 30VA
- UGEFThe cast resin outdoor voltage transformer is capable to withstanding the aggravate outdoor environmental condition.On request100/√3V, 110/√3V, 100/3V, 110/3V other voltage on request5-150VA/ 0,2-1, 3P, 6P
- BEIn three phase voltage networks with isolated neutral point which use single-pole voltage transformers, ferro-resonance may occur. These resonances are generated by the concur of single-pole voltage transformers non-linear inductance of open-circuit operation and the earthing capacitance of the network.100V100...110V0,72kV
- SB08Toroidal transformer for measuring, revenue metering (billing) and protection tasks.50-20.000A5A, 1AOn request
- SubassemblyA complete product that can be installed in power transformers, distribution transformers and switchgear straight away30-30.000A1A, 5A and others on requestAs required. For example 2,5, 5, 10, 15, 30VA
- GSRThe GSR is used for measuring and protection purposes in generator busbar systems with rated primary currents up to 15.000A.5 .. 15000A1A or 5AAccording to customer requirement
- Ø 155-6IGHDF 12The IGHDF 12 -bushing-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 5000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- Ø 130±2IGHDF 24The IGHDF 24 -bushing-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- Ø 250GSQR410The GSQR is used for protection and measurement, e.g. power generators.30 .. 15.000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- GSAG200The GSAG200 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor bushing-type current transformer can be up to 1,2kV.10-5000A1A or 5A, other options available on requestAs required. For example 10 or 15VA
- IGSG 178The IGSG 178 is used for measurement and protection in applications with vibration requirements like power generators.10-1500A1A or 5A, other options available on requestAs required. For example 15VA
- IGWR C1The IGWR C1 is used for measurement and protection in application with vibration requirements like power generators.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- IGWR D1The IGWR D1 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- IGWR D25The IGWR D25 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- M10 (20Nm)UGER C1The UGER C1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D1The UGER D1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 12kV.2/√3kV -11/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D2The UGER D2 – optional with fuse – is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D25The UGER D25 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGZR C1The UGZR C1 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGZR D25The UGZR D25 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- ø 24,5EM223The ELEQ EM223 is a current transducer for converting an alternating current of up to 400A to a 0-20mA signal.Max. 400A0-20mADoes not require an auxiliary supply
- ø 24,5EM228The ELEQ EM228 is an active current transducer for converting an alternating current of up to 1250A to an 4-20mA (standard), 0-20mA or 0-10V signal.Max. 1250A4-20mA, 0-20mA and 0-10V (on request)230Vac
- ø 24,5EM229The ELEQ EM229 is an active current transducer for converting an alternating current of up to 250A to a 4-20mA, 0-20mA of 0-10V signal.Max. 250A4-20mA and 0-20mA and 0-10V230Vac
- ø 22,7EM238The ELEQ EM238 is a two-wire transmitter for converting alternating current to a 4-20mA signal. The auxiliary supply of 10-40Vdc is included in the output circuit.Max. 600A4-20mA10-40Vdc
- ø 22,7EM303The ELEQ current relay EM303 is suitable for an alternating current of up to 100A and has a fixed switching point of 0.5A. Other switching points are available on customer specification.Max. 100A0,5A24Vdc, 110Vdc (on request)
- ø 22,7EM305The ELEQ current relay EM305 is suitable for an alternating current of up to 100A. The switching point and speed of response are adjustable.Max. 100AAdjustable24Vdc, 110Vdc (on request)
- UGEF D26The UGEF D26 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 24kV.6/√3kV -22/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- GST 170The GST170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.20-2000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GST 200The GST200 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.30-2500A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GST 170 earth faultThe GST170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.60A1AAs required. For example 1,2VA
- GSK 170 earth faultThe GSK 170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.60A1AAs required. For example 1,2VA
- SBBThe SBB are bandaged current transformers in assembly sets for installations in switchgears or cable cellars. The indoor current transformer can be used up to 0,72 kV and is maintenance-free and mountable in any position.60A -3000A1A or 5A; other options available on requestAs required. For example 0,2
- Ø 82SBM 106-54-82 ../1A for GermanyThe ESBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications. Due to its optimized design it fits around almost all bushing connectors. These current transformers are supplied with a declaration of conformity.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- Ø 82SBM 106-54-82 ../5A for GermanyThe ESBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications. Due to its optimized design it fits around almost all bushing connectors. These current transformers are supplied with a declaration of conformity.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- M12 (40Nm)IGWK C1The IGWK..C1 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWK C18The IGWK..C18 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWK D2The IGWK..D2 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWK D28The IGWK..D28 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- IGDW B200The IGDW..B200 is used for measurement and protection in applications. The cast resin insulated indoor bushing-type current transformer can be used up to 12kV.5 - 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- IGDW F350The IGDW..F350 is used for measurement and protection in applications. The cast resin insulated indoor bushing-type current transformer can be used up to 24kV.5 - 7000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- Max. ø60GSA100The GSA100 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø45GSA105The GSA105 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 600A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø60GSA 110The GSA110 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø70GSA 120The GSA120 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1250A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø72GSA 130The GSA130 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1250A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø72GSA 135The GSA135 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø110GSA 150The GSA150 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- GSA 170The GSA170 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø150GSA 200The GSA200 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 5000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø155GSA 235The GSA235 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 5000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø180GSA 250The GSA250 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 6000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø210GSA 300The GSA300 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø250GSA 350The GSA350 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø300GSA 400The GSA400 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- GSA 500The GSA500 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 15.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- M12 (40Nm)IGW A1The IGW A1 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 12kV.5 .. 800A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW A10The IGW A10 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 12kV.5 .. 600A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW B10The IGW B10 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 12kV.5 .. 800A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW C1The IGW C1 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5 .. 1500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D1The IGW D1 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5 .. 1500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D12The IGW D12 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 24kV.5 .. 1000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D2The IGW D2 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 24 kV.5 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D3The IGW D3 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 36 kV.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW E4The IGW E4 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 24 kV.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- Ø 60SVA150 B 60The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1000/5A5P20, 0,2 FS105VA, 15VA
- ø 0ERM60-D ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1/5A .. 30/5A1 or 35 - 7,5VA
- ø 22,7ERM60-E2A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.25/5A .. 400/5A0,5 or 1 or 30,5 - 12,5VA
- ø 22,7ERM60-E2A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.25/1A .. 400/1A0,5 or 1 or 30,5 - 12,5VA
- ø 24,5ERM60-E3A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.50/5A .. 600/5A0,5 or 1 or 30,5 - 12,5VA
- ø 24,5ERM60-E3A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.50/1A .. 600/1A0,5 or 1 or 30,5 - 12,5VA
- ø 24,7ERM60-E4A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.250/5A .. 600/5A0,5 or 1 or 32,5 - 10VA
- ø 24,7ERM60-E4A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.250/1A .. 600/1A0,5 or 1 or 32,5 - 10VA
- Ø 30ERM70-E4A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.600/5A .. 800/5A0,5 or 1 or Fs55 - 10VA
- Ø 30ERM70-E4A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.600/5A .. 800/5A0,5 or 1 or Fs55 - 10VA
- Ø 30,6ERM85-E6A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.750/5A .. 1500/5A0,5 or 1 or Fs51 - 20VA
- Ø 30,6ERM85-E6A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.750/1A .. 1500/1A0,5 or 1 or Fs51 - 20VA
- Ø 51ERM100-E8A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/5A .. 1600/5A0,5 or 1 or Fs51 - 30VA
- Ø 51ERM100-E8A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/1A .. 1600/1A0,5 or 1 or Fs51 - 30VA
- Ø 30ERM120-E8/2 ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/5A .. 2500/5A0,5 or 1 or Fs51 - 30VA
- Ø 31ERM120-E8/2 ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/1A .. 2500/1A0,5 or 1 or Fs51 - 30VA
- ø 0ERM60-D ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1/1A .. 30/1A1 or 35 - 7,5VA
- GSK 100The GSK 100 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 120The GSK 120 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 800A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 135The GSK 135 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 150The GSK 150 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 170The GSK 170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 200The GSK 200 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2500A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 250The GSK 250 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 6000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 300The GSK 300 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 350The GSK 350 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 400The GSK 400 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 500The GSK 500 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSRF 380The GSRF380 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -5000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 450The GSRF 450 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -8000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 540The GSRF 540 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 570The GSRF 570 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -5000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 630The GSRF 630 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 720The GSRF 720 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 810The GSRF 810 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 880The GSRF 880 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 1080The GSRF 1080 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -30000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 1150The GSRF 1150 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -30000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- UGEF E43The UGEF E43 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 17,5kV.6/√3kV -15/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- UGEF E43The UGEF E43 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 17,5kV.6/√3kV -15/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- UGEF E43The UGEF E43 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 17,5kV.6/√3kV -15/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- UGZCAK D2The UGZCAK D2 is a cast-resin insulated metal-coating indoor double-phase voltage transformer suitable for medium voltage switchgears.1,2 kV .. 22kV, other options available on request100V, 110V, 230V, other options available on requestAs required.
- Max. Ø 50SVR109The low power switchgear current transformers in SVR109 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU).5P80Contact ELEQ for details
- ø 5 mmRM17The very compact RM17 is ideal for measuring low values with a high accuracy in locations where the dimensions are critical, for instance on a three phase circuit breaker with a fase distance of 17,5mm.32/0,32A0.50,1Ω
- Max. 1000VSVUAmong other things decentralized generation (solar panels, wind turbines) is leading to an increasing number of unusual voltages, such as 690V. To still use the standard meters (400/230V), ELEQ has developed a new line of voltage transformers for low voltage.Max. 1000VMax. 400V0,2, 0,5, 1, 3
- UGZ D1The UGZ D1 is a cast-resin insulated indoor double-phase voltage transformer suitable for medium voltage switchgears. The transformer is able to measure voltage up to 12kV.1,2kV -11kV; other options available on request100V, 110V, 230V; other options available on requestAs required
- UGZCAK D1The UGZCAK D1 is a cast-resin insulated metal-coating indoor double-phase voltage transformer suitable for medium voltage switchgears.1,2 kV .. 11kV, other options available on request100V, 110V, 230V, other options available on requestAs required
- UGZ D2The UGZ D2 is a cast-resin insulated indoor double-phase voltage transformer suitable for medium voltage switchgears. The transformer is able to measure voltage up to 24kV.1,2kV -22kV; other options available on request100V, 110V, 230V; other options available on requestAs required
- UGZ E6The UGZ E6 is a cast-resin insulated indoor double-phase voltage transformer suitable for medium voltage switchgears. The transformer is able to measure voltage up to 24kV.1,2kV -22kV; other options available on request100V, 110V, 230V; other options available on requestAs required
- ø18TQ30The very compact ELEQ TQ30 split-core current transformer is especially designed for connection to digital measurement systems.60/1A .. 250/1A1 or 30,2VA
- ø 18TQ40-B ../1AThe very compact ELEQ TQ40-B split-core current transformer is especially designed for connection to digital measurement systems.100/1A .. 250/1A1 or 0,50,2VA
- ø 18TQ40-B ../5AThe very compact ELEQ TQ40-B split-core current transformer is especially designed for connection to digital measurement systems.150/5A .. 250/5A1 or 0,51VA
- ø 28TQ40-C ../1AThe very compact ELEQ TQ40-C split-core current transformer is especially designed for connection to digital measurement systems.200/1A .. 500/1A1 or 0,50,2VA
- ø 28TQ40-C ../5AThe very compact ELEQ TQ40-C split-core current transformer is especially designed for connection to digital measurement systems.250/5A .. 500/5A11VA
- ø 42TQ50-E ../1AThe very compact ELEQ TQ50-E split-core current transformer is especially designed for connection to digital measurement systems.250/1A .. 1000/1A0,5 or 1 or 30,5VA or 5VA
- ø 42TQ50-E ../5AThe very compact ELEQ TQ50-E split-core current transformer is especially designed for connection to digital measurement systems.300/5A .. 1000/5A0,5 or 1 or 30,5VA or 5VA
- 2x ø42TQ50-L ../1AThe very compact ELEQ TQ50-L split-core current transformer is especially designed for connection to digital measurement systems.250/1A .. 1000/1A0,5 or 1 or 30,5VA or 5VA
- 2x ø42TQ50-L ../5AThe very compact ELEQ TQ50-L split-core current transformer is especially designed for connection to digital measurement systems.300/5A .. 1000/5A0,5 or 1 or 30,5VA or 5VA
- Max Ø 30,6Energy Revenue LineEasy to install current transformers for revenue metering that ensure lower engineering costs and eliminates paperwork of test reports.100/5A .. 1000/5A0,5S or 0,2S0 .. 5 VA
- Max Ø 30,6Energy Revenue Line for GermanyEasy to install current transformers for revenue metering that ensure lower engineering costs and eliminates paperwork of test reports. For Germany (mit Konformitätserklärung)100/5A .. 1000/5A and 100/1A .. 1000/1A0,5S or 0,2S0 .. 5 VA
- Ø 24,5IA60B31KThese – over the full operational temperature range - accurate current transformers are suitable for measurement and for revenue metering (billing)100/5A .. 600/5A0,2S0 .. 5 VA
- Ø 36IA70B41KThese – over the full operational temperature range - accurate current transformers are suitable for measurement and for revenue metering (billing)150/5A .. 600/5A0,2S0 .. 5 VA
- Ø 43IA85B61KThese – over the full operational temperature range - accurate current transformers are suitable for measurement and for revenue metering (billing)200/5A .. 1600/5A0,2S0 .. 5 VA
- Max. Ø 350GSA Cast Resin Current TransformerGSA Cast Resin Current Transformers: Perfect, safe design offering full flexibility in housing20 .. 10000AAccording to customer requirementAccording to customer requirement
- Ø 82SBM 106-54-82 ../1AThe SBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,5 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- Ø 82SBM 106-54-82 ../5AThe SBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,5 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- Ø 45SVA100 M-classesThe SVA100 is specially designed for application in medium voltage installations as RMU’s.50/5A .. 600/5A and 50/1A .. 600/1A0,2S or 0,5S or 12 .. 10 VA
- Ø 45SVA100 P-classesThe SVA100 is specially designed for application in medium voltage installations as RMU’s.50/5A .. 600/5A and 50/1A .. 600/1A5P10 or 10P101,5 .. 6VA
- Ø 50SVA105-100-50The SVA105 is especially designed for application in medium voltage installations around insulated cables.100/5A .. 600/5A and 100/1A .. 600/1A0,2S, 0,5S, 1, 5P10, 10P101,5-10VA
- Ø 50SVA150 B 50The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.200/5A0,2 FS515VA
- Ø 50SVA150 D 50The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1500/5A5P2030VA
- Ø 60SVA150 D 60The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1250/1A or 400-150/1/1A or 600-250/1/1A5P20, 0,2 - 10P105VA
- Ø 72 mmSVA150 C 72The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1000-500/1/15P2010-5VA
- Ø 110SVA170 B 110The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.100/1A10P102VA
- Max. Ø 50SVA100The low power switchgear current transformers in SVA100 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU).5P80, 10P80Contact ELEQ for details
- Max. Ø 73SVR109 H3The current transformer for self powered relay in SVR109 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU).5P80, 10P80Contact ELEQ for details
- Ø 100SVA160 A 100One-piece cast-resin CT suitable to put on cable or cable bushing: Type SVA for earth fault detection.60/1A or 100/1ASpecial for directed Earth fault2,5VA
- WSRThe load resistors have been specially developed to bring the charge of a current transformer within 25% and 100% of the value mentioned on the type plate of the power transformer.
- VSR600In its sealable module, the VSR600 load resistor simultaneously modifies the burden of all three phases according to the required values.
- WSR600In its sealable module, the VSR600 load resistor simultaneously modifies the burden of all three phases according to the required values.
- Max. Ø 350GSK Split-Core Current TransformerGSK Split-Core Current Transformers: perfect design offering full flexibility and compliance with all regulations.50 .. 10000AAccording to customer requirementAccording to customer requirement
- ø 35TM800The TM800 Split-core Current Transformer is suitable for cable and busbar.100/5A .. 800/5A1 or 3 or Fs51 - 15VA
- ø 32TM2000The TM2000 Split-core Current Transformer is suitable for cable and busbar.1000/5A .. 2000/5A0,5 or Fs71 - 15VA
- M6/M8ZK4-M6/M8With the ZK4-M6/M8 it is possible to make a safe and simple fused voltage branch in your distribution system.400Vac2A
- 0-16UAKWith the UAK it is possible to make a safe and simple fused voltage branch in your distribution system.690Vac10A
- ø7,5RM27The very compact RM27 is ideal for measuring low values with a high accuracy in locations where the dimensions are critical, for instance on a three phase circuit breaker with a fase distance of 17,5mm.35/1A and 64/1A10,2VA
- 1,5-16VCT32The ELEQ Power Sensor combines three functions in one product: the rail terminal, the current transformer and the fused voltage tap. So the VCT32 enables both an accurate current measurement and a voltage measurement in one product.16/1A, 35/1A and 64/1A0,5, 1, 30,1VA, 0,2VA
- M4/M5ZK4Voltage tap for shunt or rail can be used to make a safe and simple fused voltage tap in your distribution system.690Vac10A
- 2,5-6UAD6(n)This UAD6 easy voltage tap allows you to tap a fused voltage from an insulated wire for measurement using one hand and without the need for additional tools.400Vac2,5-6mm
- 16mm²UAD16(n)This UAD6 easy voltage tap allows you to tap a fused voltage from an insulated wire for measurement using one hand and without the need for additional tools.400Vac6-16mm
- 35mmSummation TransformerThe very compact and highly accurate Summation Transformer makes it possible to sum the outputs from 2 or 3 ELEQ TQ split-core transformers to 1 signal to your multi instrument.1+1/1A and 1+1+1/1A10,2VA
- ø 24,5EM223The ELEQ EM223 is a current transducer for converting an alternating current of up to 400A to a 0-20mA signal.Max. 400A0-20mADoes not require an auxiliary supply
- ø 24,5EM228The ELEQ EM228 is an active current transducer for converting an alternating current of up to 1250A to an 4-20mA (standard), 0-20mA or 0-10V signal.Max. 1250A4-20mA, 0-20mA and 0-10V (on request)230Vac
- ø 24,5EM229The ELEQ EM229 is an active current transducer for converting an alternating current of up to 250A to a 4-20mA, 0-20mA of 0-10V signal.Max. 250A4-20mA and 0-20mA and 0-10V230Vac
- ø 22,7EM238The ELEQ EM238 is a two-wire transmitter for converting alternating current to a 4-20mA signal. The auxiliary supply of 10-40Vdc is included in the output circuit.Max. 600A4-20mA10-40Vdc
- ø 22,7EM303The ELEQ current relay EM303 is suitable for an alternating current of up to 100A and has a fixed switching point of 0.5A. Other switching points are available on customer specification.Max. 100A0,5A24Vdc, 110Vdc (on request)
- ø 22,7EM305The ELEQ current relay EM305 is suitable for an alternating current of up to 100A. The switching point and speed of response are adjustable.Max. 100AAdjustable24Vdc, 110Vdc (on request)
- GST 170The GST170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.20-2000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GST 200The GST200 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.30-2500A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GST 170 earth faultThe GST170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.60A1AAs required. For example 1,2VA
- GSK 170 earth faultThe GSK 170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.60A1AAs required. For example 1,2VA
- SBBThe SBB are bandaged current transformers in assembly sets for installations in switchgears or cable cellars. The indoor current transformer can be used up to 0,72 kV and is maintenance-free and mountable in any position.60A -3000A1A or 5A; other options available on requestAs required. For example 0,2
- Ø 82SBM 106-54-82 ../1A for GermanyThe ESBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications. Due to its optimized design it fits around almost all bushing connectors. These current transformers are supplied with a declaration of conformity.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- Ø 82SBM 106-54-82 ../5A for GermanyThe ESBM 106-54-82 is a low voltage current transformer for mounting around the bushing/conus connector in switchgear applications. Due to its optimized design it fits around almost all bushing connectors. These current transformers are supplied with a declaration of conformity.200/5A .. 600/5A and 50/1A .. 600/1A1 or 0,2S or 0,5S1 or 2 or 2,5 or 5 VA
- Max. ø60GSA100The GSA100 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø45GSA105The GSA105 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 600A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø60GSA 110The GSA110 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø70GSA 120The GSA120 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1250A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø72GSA 130The GSA130 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1250A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø72GSA 135The GSA135 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø110GSA 150The GSA150 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- GSA 170The GSA170 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø150GSA 200The GSA200 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 5000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø155GSA 235The GSA235 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 5000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø180GSA 250The GSA250 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 6000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø210GSA 300The GSA300 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø250GSA 350The GSA350 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Max. ø300GSA 400The GSA400 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- GSA 500The GSA500 is a cast-resin insulated bushing-type current transformer for indoor applications. They are suitable to put on cables or bus-bars.30 .. 15.000A1A or 5A, other options available on requestAs required. For example 0,2, 5P20
- Ø 60SVA150 B 60The SVA150 is specially designed for application in medium voltage installations as Ring Main Units.1000/5A5P20, 0,2 FS105VA, 15VA
- ø 0ERM60-D ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1/5A .. 30/5A1 or 35 - 7,5VA
- ø 22,7ERM60-E2A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.25/5A .. 400/5A0,5 or 1 or 30,5 - 12,5VA
- ø 22,7ERM60-E2A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.25/1A .. 400/1A0,5 or 1 or 30,5 - 12,5VA
- ø 24,5ERM60-E3A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.50/5A .. 600/5A0,5 or 1 or 30,5 - 12,5VA
- ø 24,5ERM60-E3A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.50/1A .. 600/1A0,5 or 1 or 30,5 - 12,5VA
- ø 24,7ERM60-E4A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.250/5A .. 600/5A0,5 or 1 or 32,5 - 10VA
- ø 24,7ERM60-E4A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.250/1A .. 600/1A0,5 or 1 or 32,5 - 10VA
- Ø 30ERM70-E4A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.600/5A .. 800/5A0,5 or 1 or Fs55 - 10VA
- Ø 30ERM70-E4A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.600/5A .. 800/5A0,5 or 1 or Fs55 - 10VA
- Ø 30,6ERM85-E6A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.750/5A .. 1500/5A0,5 or 1 or Fs51 - 20VA
- Ø 30,6ERM85-E6A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.750/1A .. 1500/1A0,5 or 1 or Fs51 - 20VA
- Ø 51ERM100-E8A ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/5A .. 1600/5A0,5 or 1 or Fs51 - 30VA
- Ø 51ERM100-E8A ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/1A .. 1600/1A0,5 or 1 or Fs51 - 30VA
- Ø 30ERM120-E8/2 ../5AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/5A .. 2500/5A0,5 or 1 or Fs51 - 30VA
- Ø 31ERM120-E8/2 ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1000/1A .. 2500/1A0,5 or 1 or Fs51 - 30VA
- ø 0ERM60-D ../1AFlexible, compact and reliable, those are the keywords of the (E)RM-series of ELEQ. All transformers are equipped with a sealable integrated terminal cover in a case of polycarbonate.1/1A .. 30/1A1 or 35 - 7,5VA
- GSK 100The GSK 100 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 120The GSK 120 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 800A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 135The GSK 135 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 150The GSK 150 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 170The GSK 170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 200The GSK 200 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2500A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 250The GSK 250 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 6000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 300The GSK 300 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 350The GSK 350 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 400The GSK 400 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 500The GSK 500 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- Max. Ø 50SVR109The low power switchgear current transformers in SVR109 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU).5P80Contact ELEQ for details
- ø 5 mmRM17The very compact RM17 is ideal for measuring low values with a high accuracy in locations where the dimensions are critical, for instance on a three phase circuit breaker with a fase distance of 17,5mm.32/0,32A0.50,1Ω
- Max. 1000VSVUAmong other things decentralized generation (solar panels, wind turbines) is leading to an increasing number of unusual voltages, such as 690V. To still use the standard meters (400/230V), ELEQ has developed a new line of voltage transformers for low voltage.Max. 1000VMax. 400V0,2, 0,5, 1, 3
- ø18TQ30The very compact ELEQ TQ30 split-core current transformer is especially designed for connection to digital measurement systems.60/1A .. 250/1A1 or 30,2VA
- ø 18TQ40-B ../1AThe very compact ELEQ TQ40-B split-core current transformer is especially designed for connection to digital measurement systems.100/1A .. 250/1A1 or 0,50,2VA
- ø 18TQ40-B ../5AThe very compact ELEQ TQ40-B split-core current transformer is especially designed for connection to digital measurement systems.150/5A .. 250/5A1 or 0,51VA
- ø 28TQ40-C ../1AThe very compact ELEQ TQ40-C split-core current transformer is especially designed for connection to digital measurement systems.200/1A .. 500/1A1 or 0,50,2VA
- ø 28TQ40-C ../5AThe very compact ELEQ TQ40-C split-core current transformer is especially designed for connection to digital measurement systems.250/5A .. 500/5A11VA
- ø 42TQ50-E ../1AThe very compact ELEQ TQ50-E split-core current transformer is especially designed for connection to digital measurement systems.250/1A .. 1000/1A0,5 or 1 or 30,5VA or 5VA
- ø 42TQ50-E ../5AThe very compact ELEQ TQ50-E split-core current transformer is especially designed for connection to digital measurement systems.300/5A .. 1000/5A0,5 or 1 or 30,5VA or 5VA
- 2x ø42TQ50-L ../1AThe very compact ELEQ TQ50-L split-core current transformer is especially designed for connection to digital measurement systems.250/1A .. 1000/1A0,5 or 1 or 30,5VA or 5VA
- 2x ø42TQ50-L ../5AThe very compact ELEQ TQ50-L split-core current transformer is especially designed for connection to digital measurement systems.300/5A .. 1000/5A0,5 or 1 or 30,5VA or 5VA
- ø 24,5EM223The ELEQ EM223 is a current transducer for converting an alternating current of up to 400A to a 0-20mA signal.Max. 400A0-20mADoes not require an auxiliary supply
- ø 24,5EM228The ELEQ EM228 is an active current transducer for converting an alternating current of up to 1250A to an 4-20mA (standard), 0-20mA or 0-10V signal.Max. 1250A4-20mA, 0-20mA and 0-10V (on request)230Vac
- ø 24,5EM229The ELEQ EM229 is an active current transducer for converting an alternating current of up to 250A to a 4-20mA, 0-20mA of 0-10V signal.Max. 250A4-20mA and 0-20mA and 0-10V230Vac
- ø 22,7EM238The ELEQ EM238 is a two-wire transmitter for converting alternating current to a 4-20mA signal. The auxiliary supply of 10-40Vdc is included in the output circuit.Max. 600A4-20mA10-40Vdc
- ø 22,7EM303The ELEQ current relay EM303 is suitable for an alternating current of up to 100A and has a fixed switching point of 0.5A. Other switching points are available on customer specification.Max. 100A0,5A24Vdc, 110Vdc (on request)
- ø 22,7EM305The ELEQ current relay EM305 is suitable for an alternating current of up to 100A. The switching point and speed of response are adjustable.Max. 100AAdjustable24Vdc, 110Vdc (on request)
- ø 45TQ120TQ120 is a very compact split-core current transformer suitable for low voltage systems. The unit is easy to install while the top part can be removed entirely.100/1A .. 600/1A1 or 0,5S or 5P10 or 5P201,5 - 20 VA
- ø45TQ120TQ120 is a very compact split-core current transformer suitable for low voltage systems. The unit is easy to install while the top part can be removed entirely.200/5A .. 600/5A1 or 0,5S or 0,2S2,5 - 10 VA
- Max. Ø 350GSK Split-Core Current TransformerGSK Split-Core Current Transformers: perfect design offering full flexibility and compliance with all regulations.50 .. 10000AAccording to customer requirementAccording to customer requirement
- ø 35TM800The TM800 Split-core Current Transformer is suitable for cable and busbar.100/5A .. 800/5A1 or 3 or Fs51 - 15VA
- ø 32TM2000The TM2000 Split-core Current Transformer is suitable for cable and busbar.1000/5A .. 2000/5A0,5 or Fs71 - 15VA
- GST 170The GST170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.20-2000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GST 200The GST200 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.30-2500A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GST 170 earth faultThe GST170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.60A1AAs required. For example 1,2VA
- GSK 170 earth faultThe GSK 170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars. The cast resin insulated indoor split core type current transformer can be used up to 1,2kV.60A1AAs required. For example 1,2VA
- GSK 100The GSK 100 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 120The GSK 120 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 800A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 135The GSK 135 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 150The GSK 150 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 1600A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 170The GSK 170 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 200The GSK 200 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 2500A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 250The GSK 250 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 6000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 300The GSK 300 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 350The GSK 350 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 400The GSK 400 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- GSK 500The GSK 500 are cast-resin insulated current transformers for indoor applications. They are suitable to put on cables or bus-bars.30 .. 10.000A1A or 5A; other options available on requestAs required. For example 0,5, 5P20
- ø18TQ30The very compact ELEQ TQ30 split-core current transformer is especially designed for connection to digital measurement systems.60/1A .. 250/1A1 or 30,2VA
- ø 18TQ40-B ../1AThe very compact ELEQ TQ40-B split-core current transformer is especially designed for connection to digital measurement systems.100/1A .. 250/1A1 or 0,50,2VA
- ø 18TQ40-B ../5AThe very compact ELEQ TQ40-B split-core current transformer is especially designed for connection to digital measurement systems.150/5A .. 250/5A1 or 0,51VA
- ø 28TQ40-C ../1AThe very compact ELEQ TQ40-C split-core current transformer is especially designed for connection to digital measurement systems.200/1A .. 500/1A1 or 0,50,2VA
- ø 28TQ40-C ../5AThe very compact ELEQ TQ40-C split-core current transformer is especially designed for connection to digital measurement systems.250/5A .. 500/5A11VA
- ø 42TQ50-E ../1AThe very compact ELEQ TQ50-E split-core current transformer is especially designed for connection to digital measurement systems.250/1A .. 1000/1A0,5 or 1 or 30,5VA or 5VA
- ø 42TQ50-E ../5AThe very compact ELEQ TQ50-E split-core current transformer is especially designed for connection to digital measurement systems.300/5A .. 1000/5A0,5 or 1 or 30,5VA or 5VA
- 2x ø42TQ50-L ../1AThe very compact ELEQ TQ50-L split-core current transformer is especially designed for connection to digital measurement systems.250/1A .. 1000/1A0,5 or 1 or 30,5VA or 5VA
- 2x ø42TQ50-L ../5AThe very compact ELEQ TQ50-L split-core current transformer is especially designed for connection to digital measurement systems.300/5A .. 1000/5A0,5 or 1 or 30,5VA or 5VA
- M12 (40Nm)IGWThe IGW is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 36kV.5 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M20IGHSF 12The IGHSF 12 - head-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- M20IGHSF 24The IGHSF 24 - head-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- M12 (40Nm)IGWF D26The IGWF D26 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 600A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWF E43The IGWF E43 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWF E44The IGWF E44 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWF E46The IGWF E46 is used for outdoor applications. The secondary windings are used for measurement and/or protection purposes or for special use like testing winding.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- UGECAKT D2Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation.1,5 .. 22kV230V, other options available on request600 .. 750VA
- UGZCAKT D1The UGZCAKT D1 is a cast-resin insulated metal-coating indoor double-phase voltage transformer suitable for medium voltage switchgears.1,2 kV .. 11kV, other options available on request100V, 110V, 230V, other options available on requestAs required
- M10UGZT C1Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation.1,5 .. 11kV230V, other options available on request600 .. 750VA
- M10UGZT D2Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation.1,5 .. 11kV230V, other options available on request1300 .. 2000VA
- M10 (20Nm)UGE C1The UGE C1 is used for measurement and protection in applications, especially in medium-voltage switchgears. The single pole indoor voltage transformer can be used up to 17,5kV2/√3kV – 15,4/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGE D2The UGE D2 is used for measurement and protection in applications, especially in medium-voltage switchgears. The single pole indoor voltage transformer can be used up to 24kV.2/√3kV - 22/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGE D3The UGE D3 is used for measurement and protection in applications, especially in medium-voltage switchgears. The single pole indoor voltage transformer can be used up to 36kV.2/√3kV - 33/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- UGZ C1The UGZ C1 is used for measurement and protection in applications, especially in medium-voltage switchgears. The double pole indoor voltage transformer can be used up to 12kV.1,2kV - 11kV100V or 110V, other options available on requestAs required. For example 10, 15 or 30VA
- UGECAK D1The UGECAK is a medium voltage insulated voltage transformer with screening against electric fields which enables mounting with no phase distance. This product is cast resin insulated and touch-proved.11 / √3 kV100 / √3 V or 110 / √3 V, other options available on requestAs required For example 2,5, 5, 10, 15, 30VA
- UGECAK D2The UGECAK is a medium voltage insulated voltage transformer with screening against electric fields which enables mounting with no phase distance. This product is cast resin insulated and touch-proved.22 / √3 kV100 / √3 V or 110 / √3 V, other options available on requestAs required. For example 2,5, 5, 10, 15, 30VA
- UGEFThe cast resin outdoor voltage transformer is capable to withstanding the aggravate outdoor environmental condition.On request100/√3V, 110/√3V, 100/3V, 110/3V other voltage on request5-150VA/ 0,2-1, 3P, 6P
- BEIn three phase voltage networks with isolated neutral point which use single-pole voltage transformers, ferro-resonance may occur. These resonances are generated by the concur of single-pole voltage transformers non-linear inductance of open-circuit operation and the earthing capacitance of the network.100V100...110V0,72kV
- SB08Toroidal transformer for measuring, revenue metering (billing) and protection tasks.50-20.000A5A, 1AOn request
- SubassemblyA complete product that can be installed in power transformers, distribution transformers and switchgear straight away30-30.000A1A, 5A and others on requestAs required. For example 2,5, 5, 10, 15, 30VA
- GSRThe GSR is used for measuring and protection purposes in generator busbar systems with rated primary currents up to 15.000A.5 .. 15000A1A or 5AAccording to customer requirement
- Ø 155-6IGHDF 12The IGHDF 12 -bushing-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 5000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- Ø 130±2IGHDF 24The IGHDF 24 -bushing-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- Ø 250GSQR410The GSQR is used for protection and measurement, e.g. power generators.30 .. 15.000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- GSAG200The GSAG200 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor bushing-type current transformer can be up to 1,2kV.10-5000A1A or 5A, other options available on requestAs required. For example 10 or 15VA
- IGSG 178The IGSG 178 is used for measurement and protection in applications with vibration requirements like power generators.10-1500A1A or 5A, other options available on requestAs required. For example 15VA
- IGWR C1The IGWR C1 is used for measurement and protection in application with vibration requirements like power generators.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- IGWR D1The IGWR D1 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- IGWR D25The IGWR D25 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- M10 (20Nm)UGER C1The UGER C1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D1The UGER D1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 12kV.2/√3kV -11/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D2The UGER D2 – optional with fuse – is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D25The UGER D25 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGZR C1The UGZR C1 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGZR D25The UGZR D25 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- UGEF D26The UGEF D26 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 24kV.6/√3kV -22/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- M12 (40Nm)IGWK C1The IGWK..C1 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWK C18The IGWK..C18 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWK D2The IGWK..D2 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGWK D28The IGWK..D28 is used for measurement and protection in applications. This model is specially designed for an extended creepage distance.5 - 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- IGDW B200The IGDW..B200 is used for measurement and protection in applications. The cast resin insulated indoor bushing-type current transformer can be used up to 12kV.5 - 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- IGDW F350The IGDW..F350 is used for measurement and protection in applications. The cast resin insulated indoor bushing-type current transformer can be used up to 24kV.5 - 7000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW A1The IGW A1 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 12kV.5 .. 800A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW A10The IGW A10 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 12kV.5 .. 600A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW B10The IGW B10 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 12kV.5 .. 800A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW C1The IGW C1 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5 .. 1500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D1The IGW D1 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5 .. 1500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D12The IGW D12 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 24kV.5 .. 1000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D2The IGW D2 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 24 kV.5 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW D3The IGW D3 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 36 kV.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- M12 (40Nm)IGW E4The IGW E4 is used for measurement and protection in applications. The cast resin insulated indoor supporting-type current transformer can be used up to 24 kV.5 .. 2500A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- GSRF 380The GSRF380 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -5000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 450The GSRF 450 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -8000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 540The GSRF 540 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 570The GSRF 570 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -5000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 630The GSRF 630 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 720The GSRF 720 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 810The GSRF 810 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 880The GSRF 880 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 1080The GSRF 1080 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -30000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 1150The GSRF 1150 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -30000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- UGEF E43The UGEF E43 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 17,5kV.6/√3kV -15/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- UGEF E43The UGEF E43 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 17,5kV.6/√3kV -15/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- UGEF E43The UGEF E43 is used for measurement and/or protection or for residual voltage winding in outdoor applications. The single pole outdoor voltage transformer can be used up to 17,5kV.6/√3kV -15/√3kV100/√3V or 110/√3V; other options available on requestAs required. For example 10, 15, 30VA
- UGZCAK D2The UGZCAK D2 is a cast-resin insulated metal-coating indoor double-phase voltage transformer suitable for medium voltage switchgears.1,2 kV .. 22kV, other options available on request100V, 110V, 230V, other options available on requestAs required.
- UGZ D1The UGZ D1 is a cast-resin insulated indoor double-phase voltage transformer suitable for medium voltage switchgears. The transformer is able to measure voltage up to 12kV.1,2kV -11kV; other options available on request100V, 110V, 230V; other options available on requestAs required
- UGZCAK D1The UGZCAK D1 is a cast-resin insulated metal-coating indoor double-phase voltage transformer suitable for medium voltage switchgears.1,2 kV .. 11kV, other options available on request100V, 110V, 230V, other options available on requestAs required
- UGZ D2The UGZ D2 is a cast-resin insulated indoor double-phase voltage transformer suitable for medium voltage switchgears. The transformer is able to measure voltage up to 24kV.1,2kV -22kV; other options available on request100V, 110V, 230V; other options available on requestAs required
- UGZ E6The UGZ E6 is a cast-resin insulated indoor double-phase voltage transformer suitable for medium voltage switchgears. The transformer is able to measure voltage up to 24kV.1,2kV -22kV; other options available on request100V, 110V, 230V; other options available on requestAs required
- SB08Toroidal transformer for measuring, revenue metering (billing) and protection tasks.50-20.000A5A, 1AOn request
- SubassemblyA complete product that can be installed in power transformers, distribution transformers and switchgear straight away30-30.000A1A, 5A and others on requestAs required. For example 2,5, 5, 10, 15, 30VA
- GSRThe GSR is used for measuring and protection purposes in generator busbar systems with rated primary currents up to 15.000A.5 .. 15000A1A or 5AAccording to customer requirement
- Ø 155-6IGHDF 12The IGHDF 12 -bushing-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 5000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- Ø 130±2IGHDF 24The IGHDF 24 -bushing-type current transformer is capable to withstanding the outdoor environmental condition.10 .. 3000A1A or 5A, other options available on requestAs required. For example 0,2, 0,5, 5P20
- GSRF 380The GSRF380 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -5000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 450The GSRF 450 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -8000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 540The GSRF 540 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 570The GSRF 570 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -5000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 630The GSRF 630 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 720The GSRF 720 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 810The GSRF 810 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 880The GSRF 880 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -15000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 1080The GSRF 1080 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -30000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- GSRF 1150The GSRF 1150 are cast-resin insulated ring-type current transformers and can be used for measurement and protection in outdoor applications. They are suitable to put on cables or bus-bars. The outdoor ring-type current transformer can be used up to 0,72kV.100A -30000A1A or 5A; other options available on requestAs required. For example 10VA, 15VA
- Ø 250GSQR410The GSQR is used for protection and measurement, e.g. power generators.30 .. 15.000A1A or 5A, other options available on requestAs required. For example 0,2S, 5P10
- GSAG200The GSAG200 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor bushing-type current transformer can be up to 1,2kV.10-5000A1A or 5A, other options available on requestAs required. For example 10 or 15VA
- IGSG 178The IGSG 178 is used for measurement and protection in applications with vibration requirements like power generators.10-1500A1A or 5A, other options available on requestAs required. For example 15VA
- IGWR C1The IGWR C1 is used for measurement and protection in application with vibration requirements like power generators.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- IGWR D1The IGWR D1 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- IGWR D25The IGWR D25 is used for measurement and protection in applications with vibration requirements like power generators. The cast resin insulated indoor supporting-type current transformer can be used up to 17,5kV.5-1500A1A or 5A, other options available on requestAs required. For example 2,5, 10 or 30VA
- M10 (20Nm)UGER C1The UGER C1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D1The UGER D1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 12kV.2/√3kV -11/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D2The UGER D2 – optional with fuse – is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGER D25The UGER D25 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGZR C1The UGZR C1 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA
- M10 (20Nm)UGZR D25The UGZR D25 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV.2/√3kV -15/√3kV100/√3V or 110/√3V, other options available on requestAs required. For example 10, 15 or 30VA