- UMG96The UMG96 is a compact multifunctional 4-quadrant meter for measuring and monitoring electrical parameters (True-RMS) in low and medium voltage networks.
- ø 18
TQ30 ../333mVThe very compact ELEQ TQ30 split-core current transformer is especially designed for connection to digital measurement systems.
TQ90The compact ELEQ TQ90 split-core current transformer is specifically designed for the measurement of large cables and multiple cables. It can be connected to digital measuring systems.- Max. Ø 50
TQ105TQ105 is a very compact split-core current transformer suitable for low voltage systems. The unit is easy to install while the top part can be removed entirely.
WDIV96-EThe WDIV96‑E is an electronic meter designed for accurate measurement of active power and power factor in single- or three-phase networks, with balanced or unbalanced loads. With an accuracy class of 1.5, it is ideal for monitoring and optimizing energy consumption in industrial and commercial installations.
CDIV96-EThe CDIV96-E is an electronic meter for accurate measurement of active power and power factor in single- or three-phase networks, with balanced or unbalanced loads. With an accuracy class of 1.5, it is designed for indoor use to monitor and optimize energy performance in industrial and commercial installations.- AC
EIV..-EThe EIV..-E series comprises electromagnetic analogue instruments for measuring AC current and AC voltage. These meters feature a moving iron measurement system and are designed to display true RMS values of AC voltage or current over a frequency range of 15 Hz to 100 Hz. With an accuracy class of 1.5, they provide reliable performance for industrial and commercial applications indoors.
BEIV..-EThe BEIV..-E series combines a bimetal sensing system with an electromagnetic measurement system for AC measurements. These meters are capable of recording both direct readings (electromagnetic) and delayed thermal effect readings (bimetal). They are designed for measuring AC current with and without thermal delay and are suitable for assessing thermal loads in transformers, cables, electric machines, and other AC installations.
BIV..-EThe BIV..-E series are bimetal instruments designed to measure maximum current values with an integrated thermal (delay) measurement characteristic. They are ideal for testing the thermal load of transformers, cables, electric machines, and other AC installations. The bimetal sensing system reacts to the thermal effects of current (with delay), providing measurements that closely reflect real thermal stress conditions.- Ø 7 cmRogowski coilDue to its specific features, the ELEQ Rogowski is an excellent solution for current measurement and can be used in a wide range of applications where traditional current transformers are not the adequate solution due to size, weight or due to limited access. ELEQ Rogowski coils have a wide range without saturation.
MI456The MI456 is a measurement transducer that converts DC voltage in to an 4-20mA output signal.- 100A - 5000AMultiscale Rogowski integratorThe multiscale Rogowski integrator is a current converter in a compact DIN rail enclosure. The integrator is provided with a push button for an easy scale selection, offering a wide range of applications with a single coil and integrator.
- Ø 7 cmRogowski coil setDue to its specific features, the ELEQ Rogowski is an excellent solution for current measurement and can be used in a wide range of applications where traditional current transformers are not the adequate solution due to size, weight or due to limited access. ELEQ Rogowski coils have a wide range without saturation.
- M10 (20Nm)
UGZR D25The UGZR D25 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV. - M10 (20Nm)
UGER C1The UGER C1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV. - M10 (20Nm)
UGER D1The UGER D1 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 12kV. - M10 (20Nm)
UGER D2The UGER D2 – optional with fuse – is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV. - M10 (20Nm)
UGER D25The UGER D25 is used for measurement and protection in applications with vibration requirements like power generators. The single pole indoor voltage transformer can be used up to 17,5kV. - M10 (20Nm)
UGZR C1The UGZR C1 is used for measurement and protection in applications with vibration requirements like power generators. The double pole indoor voltage transformer can be used up to 17,5kV.
UGZ C1The UGZ C1 is used for measurement and protection in applications, especially in medium-voltage switchgears. The double pole indoor voltage transformer can be used up to 12kV.