Products Energy Management

ELEQ Split-Core Current Transformer, Model TQ30, TQ40-B, TQ40-C, TQ50-E, TQ50-L
01 Deelbare Stroomtransformatoren, model TQ
4M3Q02 4M3Q03 4M3Q05 4M3Q07 4M3Q08 4M3Q09 4Q3B02 4Q3B03 4Q3B05 4Q3B07 4Q3B08 4Q3B09 4Q3B10 4Q4B05 4Q4B07 4Q4B08 4Q4B09 4Q4B10 4Q4B58 4Q4B59 4Q4B60 4Q4C09 4Q4C10 4Q4C11 4Q4C12 4Q4C13 4Q4C60 4Q4C61 4Q4C62 4Q4C63 4Q5E10 4Q5E11 4Q5E12 4Q5E13 4Q5E14 4Q5E15 4Q5E16 4Q5E17 4Q5E61 4Q5E62 4Q5E63 4Q5E64 4Q5E65 4Q5E66 4Q5E67 4Q5L10 4Q5L11 4Q5L12 4Q5L13 4Q5L14 4Q5L15 4Q5L16 4Q5L17 4Q5L61 4Q5L62 4Q5L63 4Q5L64 4Q5L65 4Q5L66 4Q5L67

Split-core current transformer according to IEC 61869-2 for easy mounting in existing installation

  • Current transformer according to IEC61869-2
  • Current ratios from 60/1A up to 1000/5A, up to class 0,5
  • For use around insulated cables up to 2x 42mm
  • Colour-coded leads included
ELEQ Split-Core Current Transformer, Model TQ120
02 ELEQ Deelbare Stroomtransformatoren TQ120
4Q12F90 4Q12F92 4Q12F93 4Q12F94 4Q12F09 4Q12F11 4Q12F12 4Q12F13 4Q12F14 4Q12F59 4Q12F61 4Q12F62 4Q12F63 4Q12F64

Compact split-core current transformer for easy mounting in new and existing low and medium voltage systems for protection and measurement purposes

  • Current transformer according to IEC61869-2
  • Current ratios from 100 to 600/1A and from 100 to 600/5A
  • For use around insulated cables up to 45mm
  • Temperature range -40C up to +60C
  • Primarily for use around cables with conus connector
ELEQ Compact Current Transformer, Model RM27
03 Compact Current Transformer, Model RM27
4R2746 4R2747 411884

Very compact IEC current transformer suitable for mounting on circuit breaker

  • Current transformer according to IEC61869-2
  • Current ratios 35/1, 64/1A, class 1
  • Primary window suitable for insulated cable maximum 7.5mm
  • Also suitable for use on 3 phase circuit breaker with fase distance
  • of 17.5mm
  • Optional: screw mounting or mounting on a DIN-rail
ELEQ Power Transformer, Model VCT32
10 Power Sensor VCT32
5VCT01 5VCT02 5VCT03

Space saving and easy to mount rail terminal with integrated current transformer and fused terminal

  • Current ratios 16/1A, 35/1A and 64/1A, up to class 0,5 (IEC 61869-2)
  • Suitable for fuse with breaking capacity up to 70kA
  • KEMA-KEUR certified
ELEQ Easy Voltage Taps for Rail, Model UAK, ZK4-M6, ZK4-M8
30 ELEQ Easy Voltage Taps voor rail, model UAK, ZK4-M6, ZK4-M8
500040 500042 500045 500030 500031

Fused terminal for safely and easy tapping voltage from busbar or rail

  • Suitable for fuse with breaking capacity up to 70kA
  • KEMA-KEUR certified
ELEQ Easy Voltage Taps for Wire, Model UAD6, UAD16
40 Easy Voltage Tap voor draad, model UAD6 / UAD16
500072R 500073R 500074R 500070 500071 500075 500011

Fused terminal for safely and easy tapping voltage from wire

  • Including 5x25mm, 2A fuse
  • UAD6: for insulated 2,5-6mm2 conductors
  • UAD16: for insulated 10-16mm2 conductors
ELEQ Compact Current Transformer, Model DRT49A12
50 hoedrailtransformator DRT49A12
4M12S1

Compact Current Transformer designed for energy measurement. Very reliable, no soldering or crimping transitions

  • Current ranges 16, 32 and 64A
  • High accuracy (class 1)
  • Integrated rail mounting
  • Super compact
Summation Transformer for TQ-line
60 Summation Transformer
4D8001 4D8002

The very compact and highly accurate Summation Transformer makes it possible to sum the outputs from 2 or 3 ELEQ TQ split-core transformers to 1 signal to your multi instrument.

  • Specially designed for a grid with dual or triple parallel cables for each phase
  • Even suitable when cables are not close to each other
  • Available with different ratios
  • Up to 9 inputs possible on request
Background 2012