| FAGET Load resistors to raise the secondary load of current transformers, model WSR60 |
 |
- Especially developed for accounting purposes
- Standard ranges 1, 1,5, 2,5 or 4VA
- Modern housing with high contact safety
- Easy to mount on top hat rail
- Compact dimensions (30x60x80mm)
- Tested for heat development
- Bifilar coil means no extra phase angle error in kWh-measurement
|
| Completely assembled 3 phase box with load resistors for voltage transformers, model VSR600 |
 |
- Especially developed for accounting purposes
- Suitable for ../100V & ../110V
- Star connection, common zero
- Sealable
- Provided with cable input PG13.5
- Box incl. fuses 0.5A
- Environmental temperature max. 50°C
- With thermal protection
- Dimensions (281x105x73mm)
|
| Completely assembled 3 phase box with load resistors for current transformers, model WSR600 |
 |
- Especially developed for accounting purposes
- Maximal burden 3 x 14W
- Suitable for ../1A and ../5A
- Sealable
- Provided with cable input PG13.5
- Environmental temperature max. 50ºC
- Dimensions (281x105x73mm)
|
| FAGET Fuse holder for miniature fuse links, model ZK4 |
 |
- Compact, easy to mount fuse terminal
- Direct connection to busbar
- Short circuit current up to 70kA at 400V with fuse link 1A (35kA with fuse link 6.3A)
- KEMA approval
- Width range of current branch guards
|
| FAGET Busbar terminal for voltage tension, model UAK |
 |
- Connects instruments to live busbars
- Model with fuse directly on rail
- Installed directly onto busbar with insulated Allen key driver bolt M8
- Installation is a one handed exercise
- High short circuit rating:10kA@400V/50Hz (10A)
- High short circuit rating:70kA@400V/50Hz (up to 6.3A fused)
- Busbar connection via Allen key bolt M8
- KEMA approval
|
| ELEQ Easy Voltage Tap for wires, model UAD16 |
 |
- One-handed and safe tapping of voltage for measurement purposes
- No tools needed
- Safe mounting
- Including 5x25mm fuse
- For insulated 4-16mm2 conductors, pliable, stranded en solid
- Breaking capacity 6kA/400/50Hz
|
| ELEQ Choke module for supressing ferro-resonance |
 |
- To prevent ferroresonance voltage transformers
- To be connected with the protection winding
- Suppress upper and lower harmonics
- Equipped with coil and resistance
- Assembled in solid stealcase housing 222x190x229mm
- Different models for differen Burden
|
| FAGET Shunts for measuring purposes |
 |
- Width range of shunts up to 8000A
- High quality
- Models in open construction and in modern housing with high contact safety, easy to mount on top-hat rail
- Heavy overloading possible
|
| Synchronoscope SQ0204 and SQ0214 |
 |
- Modern synchronoscope with voltage, frequency and phase angle measurement on LCD display
- Relay output for synchronizing
- Simple parameter adjustement on backpanel
- Dead bus functionality
- Delivery from stock
|
| kWh meter single and three phase DIN rail mounting |
 |
- Compact housing
- Available for single and three phase measurement
- DIN rail mounting
- Sharp price level
- Delivery from stock
- 2KWH01 - DRM100 1 phase direct (max. 25A)
- 2KWH02 - DRM75 1 phase direct (max. 100A)
- 2KWH03 - DRM1250 3 phase ../5A currenttransformer
- 2KWH04 - DRM1250 3 phase direct (max. 90A)
|