Power transport and distribution |
< back |
| ELEQ Current transformer systems |
 |
- Primary current up to 30.000A
- Suitable for all special applications in measurement protection and accounting
- Patented subassembly constructions
- Subassembly construction tested and reported as one set
- Colour coded secondary leads
|
| ELEQ Cast resin current transformers for indoor or outdoor application, model GSA(F) |
 |
- Primary current from 20A up to 10kA
- For measurement, protection and billing purposes
- Models for indoor and outdoor applications
- Max. 3 measurements in one housing
- Various extra parts available to mount the transformer in any position you want.
- Various window sizes Ø 90….350mm
- PTB and KEMA approved for fiscal measurements
|
| ELEQ Split-core cast resin current transformers for indoor or outdoor application, model GSK(F) |
 |
- Primary current from 50A up to 10kA
- For measurement, protection and billing purposes
- Very flexible in dimensions
- Split-core, applicable in existing installations
- Various window sizes Ø 90….350mm
|
| ELEQ Medium voltage insulated current transformers for indoor application, model IGW |
 |
- Primary current from 5A up to 3000A
- For measurement, protection and billing purposes
- Rated insulation level up to 36kV
- Max. 3 measurements in one housing
- Upon request models with capacitive voltage divider deliverable (for voltage indication)
- PTB and KEMA approved for fiscal measurements
|
| ELEQ Medium voltage insulated voltage transformers for indoor application, model UGE/UGZ |
 |
- Measuring voltage up to 24kV
- One-pole insulated, model UGE
- Two-pole insulated, model UGZ
- Maximum insulation level 24/50/125kV
- PTB and KEMA approved for fiscal measurements
|
| ELEQ Cast-resin current transformers for indoor application or construction under oil, type GSR |
 |
- Primary current from 50A up to 15kA
- For measurement, protection and billing purposes
|
| ELEQ Current transformer for earthfault detection |
 |
- One-piece cast-resin current transformer SVA160A100 for earth fault detection.
- Maximum cable diameter = 100mm.
|
| ELEQ Current transformer for "CT Powered"relay |
 |
- "low power"
- For application in RMU's in combination with
- Woodward SEG WIC1
- ABB REJ603
- Areva MiCOM P114S
- Measuring current 8-600A in 1 model
|
| ELEQ WI-WIC |
 |
- Convertor from WI to WIC
- 1 module, 3 phases
- Remplacement of WI transformers not necessary
- Cost effective
|
| ELEQ Protection transformer, model SVR 109 |
 |
- Specially designed for MV switchgears
- Solutions available from 16 up to 896A
- Output current 0.075A
- Cable length 110mm or other length on request
- Standard connector code FKCVR 2.5/ 4-ST
- Solid, reliable cast resin product
- Dimensions (LxWxH) 109-70-50mm
- Primary cable diameter max. 50mm
|
| ELEQ Splitcore protection transformer, model GSK 170 |
 |
- * In design
- Split-core, applicable for existing installations
- Solutions available from 16 up to 896A
- Output current 0.075A
- Maximum Cable diameter 60mm
- Solid, reliable cast resin product
- Dimensions (LxWxH) 170x120x218mm
|
| ELEQ Converter, model IMF 120 |
 |
- * In design
- Product converts from WI, 1A or 5A signal to the CTPR standard (output current 0.075A)
- One unit for all 3 Phases
- Easy to install on a mounting plate
- Direct applicalbe without re-wiring
- Pluggable connectors
- Dimensions (LxWxH) 113x117x120mm
|